368d6fafea
Code backup
145 lines
5.0 KiB
Plaintext
145 lines
5.0 KiB
Plaintext
3834979
|
||
WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
|
||
|
||
Inv 1: 7E060F94-27
|
||
Inv 2: 7E058F53-65
|
||
Inv 3: 7E058F82-94
|
||
|
||
|
||
https://monitoringapi.solaredge.com/3834979/details.json?api_key=WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
|
||
|
||
|
||
https://monitoringapi.solaredge.com/equipment/3834979/7E060F94-27/data.json?startTime=2023-08-22%2016:00:00&endTime=2023-08-22%2017:00:00&api_key=WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
|
||
|
||
https://monitoringapi.solaredge.com/equipment/3834979/7E060F94-27/data.json?startTime=2023-08-22%2011:00:00&endTime=2023-08-22%2013:00:00&api_key=WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
|
||
|
||
InverterMode
|
||
OFF – Off
|
||
SLEEPING – night mode
|
||
STARTING – pre-production
|
||
MPPT – production
|
||
THROTTLED – Forced power reduction
|
||
SHUTTING_DOWN – Shutdown procedure
|
||
FAULT – error mode
|
||
STANDBY – maintenance
|
||
LOCKED_STDBY – standby mode lock
|
||
LOCKED_FIRE_FIGHTERS – fire-fighters lock mode
|
||
LOCKED_FORCE_SHUTDOWN – forced shutdown from server
|
||
LOCKED_COMM_TIMEOUT – communication timeout
|
||
LOCKED_INV_TRIP – inverter self- lock trip
|
||
LOCKED_INV_ARC_DETECTED – inverter self-lock on arc detection
|
||
LOCKED_DG – inverter lock due to DG mode enable
|
||
LOCKED_PHASE_BALANCER – inverter lock due to phase imbalance (1ph, Australia only)
|
||
LOCKED_PRE_COMMISSIONING – inverter lock due to pre-commissioning
|
||
LOCKED_INTERNAL – inverter lock due to an undisclosed internal reason
|
||
|
||
{
|
||
"details": {
|
||
"id": 3834979,
|
||
"name": "PAL S.R.L.",
|
||
"accountId": 53350,
|
||
"status": "Active",
|
||
"peakPower": 281.6,
|
||
"lastUpdateTime": "2023-08-22",
|
||
"installationDate": "2023-08-03",
|
||
"ptoDate": null,
|
||
"notes": "",
|
||
"type": "Optimizers & Inverters",
|
||
"location": {
|
||
"country": "Italy",
|
||
"city": "Levada",
|
||
"address": "Via delle Industrie 2",
|
||
"address2": "",
|
||
"zip": "31047",
|
||
"timeZone": "Europe/Rome",
|
||
"countryCode": "IT"
|
||
},
|
||
"primaryModule": {
|
||
"manufacturerName": "Trina Solar Energy",
|
||
"modelName": "TSM-400DE09.08 (Vertex S)",
|
||
"maximumPower": 400.0,
|
||
"temperatureCoef": -0.34
|
||
},
|
||
"uris": {
|
||
"SITE_IMAGE": "/site/3834979/siteImage/dji_fly_20230727_145240_347_1690462367581_photo_optimized-min.jpg",
|
||
"DATA_PERIOD": "/site/3834979/dataPeriod",
|
||
"INSTALLER_IMAGE": "/site/3834979/installerImage/nuovo%2520MARCHIO%2520SAIEL.JPG",
|
||
"DETAILS": "/site/3834979/details",
|
||
"OVERVIEW": "/site/3834979/overview"
|
||
},
|
||
"publicSettings": {
|
||
"isPublic": false
|
||
}
|
||
}
|
||
}
|
||
|
||
{
|
||
"Inventory": {
|
||
"meters": [{
|
||
"name": "Contatore di energia esportata",
|
||
"manufacturer": "SolarEdge",
|
||
"model": "SE-MTR-3Y-400V-A",
|
||
"firmwareVersion": "78",
|
||
"connectedTo": "Inverter 1",
|
||
"connectedSolaredgeDeviceSN": "7E060F94-27",
|
||
"type": "FeedIn",
|
||
"form": "physical",
|
||
"SN": "606922731"
|
||
}, {
|
||
"name": "Contatore di energia importata",
|
||
"manufacturer": "SolarEdge",
|
||
"model": "SE-MTR-3Y-400V-A",
|
||
"firmwareVersion": "78",
|
||
"connectedTo": "Inverter 1",
|
||
"connectedSolaredgeDeviceSN": "7E060F94-27",
|
||
"type": "Purchased",
|
||
"form": "physical",
|
||
"SN": "606922731"
|
||
}, {
|
||
"name": "Autoconsumo",
|
||
"firmwareVersion": "",
|
||
"connectedTo": "Inverter 1",
|
||
"connectedSolaredgeDeviceSN": "7E060F94-27",
|
||
"type": "SelfConsumption",
|
||
"form": "virtual"
|
||
}, {
|
||
"name": "Contatore di energia utilizzata",
|
||
"firmwareVersion": "",
|
||
"connectedTo": "Inverter 1",
|
||
"connectedSolaredgeDeviceSN": "7E060F94-27",
|
||
"type": "Consumption",
|
||
"form": "virtual"
|
||
}
|
||
],
|
||
"sensors": [],
|
||
"gateways": [],
|
||
"batteries": [],
|
||
"inverters": [{
|
||
"name": "Inverter 1",
|
||
"manufacturer": "SolarEdge",
|
||
"model": "SE66.6K-RW00IBNQ4",
|
||
"communicationMethod": "ETHERNET",
|
||
"cpuVersion": "4.18.518",
|
||
"SN": "7E060F94-27",
|
||
"connectedOptimizers": 88
|
||
}, {
|
||
"name": "Inverter 2",
|
||
"manufacturer": "SolarEdge",
|
||
"model": "SE100K-RW00IBNQ4",
|
||
"communicationMethod": "RS485",
|
||
"cpuVersion": "4.18.518",
|
||
"SN": "7E058F53-65",
|
||
"connectedOptimizers": 133
|
||
}, {
|
||
"name": "Inverter 3",
|
||
"manufacturer": "SolarEdge",
|
||
"model": "SE100K-RW00IBNQ4",
|
||
"communicationMethod": "RS485",
|
||
"cpuVersion": "4.18.518",
|
||
"SN": "7E058F82-94",
|
||
"connectedOptimizers": 133
|
||
}
|
||
]
|
||
}
|
||
}
|