Code backup
This commit is contained in:
2026-05-10 16:59:01 +02:00
commit 368d6fafea
796 changed files with 315310 additions and 0 deletions
+144
View File
@@ -0,0 +1,144 @@
3834979
WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
Inv 1: 7E060F94-27
Inv 2: 7E058F53-65
Inv 3: 7E058F82-94
https://monitoringapi.solaredge.com/3834979/details.json?api_key=WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
https://monitoringapi.solaredge.com/equipment/3834979/7E060F94-27/data.json?startTime=2023-08-22%2016:00:00&endTime=2023-08-22%2017:00:00&api_key=WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
https://monitoringapi.solaredge.com/equipment/3834979/7E060F94-27/data.json?startTime=2023-08-22%2011:00:00&endTime=2023-08-22%2013:00:00&api_key=WPZI7125FEP6WQBQX9G6PKFL7R1V8Z8Y
InverterMode
OFF Off
SLEEPING night mode
STARTING pre-production
MPPT production
THROTTLED Forced power reduction
SHUTTING_DOWN Shutdown procedure
FAULT error mode
STANDBY maintenance
LOCKED_STDBY standby mode lock
LOCKED_FIRE_FIGHTERS fire-fighters lock mode
LOCKED_FORCE_SHUTDOWN forced shutdown from server
LOCKED_COMM_TIMEOUT communication timeout
LOCKED_INV_TRIP inverter self- lock trip
LOCKED_INV_ARC_DETECTED inverter self-lock on arc detection
LOCKED_DG inverter lock due to DG mode enable
LOCKED_PHASE_BALANCER inverter lock due to phase imbalance (1ph, Australia only)
LOCKED_PRE_COMMISSIONING inverter lock due to pre-commissioning
LOCKED_INTERNAL inverter lock due to an undisclosed internal reason
{
"details": {
"id": 3834979,
"name": "PAL S.R.L.",
"accountId": 53350,
"status": "Active",
"peakPower": 281.6,
"lastUpdateTime": "2023-08-22",
"installationDate": "2023-08-03",
"ptoDate": null,
"notes": "",
"type": "Optimizers & Inverters",
"location": {
"country": "Italy",
"city": "Levada",
"address": "Via delle Industrie 2",
"address2": "",
"zip": "31047",
"timeZone": "Europe/Rome",
"countryCode": "IT"
},
"primaryModule": {
"manufacturerName": "Trina Solar Energy",
"modelName": "TSM-400DE09.08 (Vertex S)",
"maximumPower": 400.0,
"temperatureCoef": -0.34
},
"uris": {
"SITE_IMAGE": "/site/3834979/siteImage/dji_fly_20230727_145240_347_1690462367581_photo_optimized-min.jpg",
"DATA_PERIOD": "/site/3834979/dataPeriod",
"INSTALLER_IMAGE": "/site/3834979/installerImage/nuovo%2520MARCHIO%2520SAIEL.JPG",
"DETAILS": "/site/3834979/details",
"OVERVIEW": "/site/3834979/overview"
},
"publicSettings": {
"isPublic": false
}
}
}
{
"Inventory": {
"meters": [{
"name": "Contatore di energia esportata",
"manufacturer": "SolarEdge",
"model": "SE-MTR-3Y-400V-A",
"firmwareVersion": "78",
"connectedTo": "Inverter 1",
"connectedSolaredgeDeviceSN": "7E060F94-27",
"type": "FeedIn",
"form": "physical",
"SN": "606922731"
}, {
"name": "Contatore di energia importata",
"manufacturer": "SolarEdge",
"model": "SE-MTR-3Y-400V-A",
"firmwareVersion": "78",
"connectedTo": "Inverter 1",
"connectedSolaredgeDeviceSN": "7E060F94-27",
"type": "Purchased",
"form": "physical",
"SN": "606922731"
}, {
"name": "Autoconsumo",
"firmwareVersion": "",
"connectedTo": "Inverter 1",
"connectedSolaredgeDeviceSN": "7E060F94-27",
"type": "SelfConsumption",
"form": "virtual"
}, {
"name": "Contatore di energia utilizzata",
"firmwareVersion": "",
"connectedTo": "Inverter 1",
"connectedSolaredgeDeviceSN": "7E060F94-27",
"type": "Consumption",
"form": "virtual"
}
],
"sensors": [],
"gateways": [],
"batteries": [],
"inverters": [{
"name": "Inverter 1",
"manufacturer": "SolarEdge",
"model": "SE66.6K-RW00IBNQ4",
"communicationMethod": "ETHERNET",
"cpuVersion": "4.18.518",
"SN": "7E060F94-27",
"connectedOptimizers": 88
}, {
"name": "Inverter 2",
"manufacturer": "SolarEdge",
"model": "SE100K-RW00IBNQ4",
"communicationMethod": "RS485",
"cpuVersion": "4.18.518",
"SN": "7E058F53-65",
"connectedOptimizers": 133
}, {
"name": "Inverter 3",
"manufacturer": "SolarEdge",
"model": "SE100K-RW00IBNQ4",
"communicationMethod": "RS485",
"cpuVersion": "4.18.518",
"SN": "7E058F82-94",
"connectedOptimizers": 133
}
]
}
}